---
title: "Security Lighting Liverpool | CCTV Power &amp; Floodlights | Fix Electrical (NW) Ltd"
description: "Security lighting and CCTV power installation in Liverpool. PIR floodlights, dusk-till-dawn lighting, camera and doorbell supplies. NAPIT approved, £2m insured, free quote."
lang: en-GB
json-ld: |
  [
    {
      "@context": "https://schema.org",
      "@type": "Organization",
      "@id": "#organization",
      "name": "Fix Electrical (NW) Ltd",
      "alternateName": "Fix Electrical",
      "url": "https://fixelectricalnw.co.uk/",
      "logo": "https://fixelectricalnw.co.uk/favicon.png",
      "telephone": "+447782498471",
      "email": "info@fixelectricalnw.co.uk",
      "address": {
        "@type": "PostalAddress",
        "streetAddress": "",
        "addressLocality": "Liverpool",
        "addressRegion": "Merseyside",
        "postalCode": "",
        "addressCountry": "GB"
      },
      "sameAs": [
        "https://www.instagram.com/fixelectrical/",
        "https://share.google/aiTuBpl9JTZQS1Dfc"
      ]
    },
    {
      "@context": "https://schema.org",
      "@type": "WebSite",
      "@id": "#website",
      "name": "Fix Electrical (NW) Ltd",
      "url": "https://fixelectricalnw.co.uk/",
      "publisher": {
        "@id": "#organization"
      },
      "inLanguage": "en-GB"
    },
    {
      "@context": "https://schema.org",
      "@type": "Service",
      "serviceType": "Security Lighting & CCTV Power",
      "name": "Security Lighting & CCTV Power, Fix Electrical (NW) Ltd",
      "description": "Security lighting and CCTV power installation in Liverpool. PIR floodlights, dusk-till-dawn lighting, camera and doorbell supplies. NAPIT approved, £2m insured, free quote.",
      "areaServed": {
        "@type": "City",
        "name": "Liverpool"
      },
      "provider": {
        "@type": "Electrician",
        "name": "Fix Electrical (NW) Ltd",
        "telephone": "+447782498471",
        "email": "info@fixelectricalnw.co.uk",
        "address": {
          "@type": "PostalAddress",
          "streetAddress": "",
          "addressLocality": "Liverpool",
          "addressRegion": "Merseyside",
          "postalCode": "",
          "addressCountry": "GB"
        }
      }
    },
    {
      "@context": "https://schema.org",
      "@type": "FAQPage",
      "mainEntity": [
        {
          "@type": "Question",
          "name": "How much does security lighting cost to install?",
          "acceptedAnswer": {
            "@type": "Answer",
            "text": "It depends on the number of fittings, cable routes and whether a new circuit is needed. We quote a fixed price after a free on-site look."
          }
        },
        {
          "@type": "Question",
          "name": "Can you fit lighting to an existing circuit?",
          "acceptedAnswer": {
            "@type": "Answer",
            "text": "Often yes, where the circuit has capacity and suitable protection. If not, we'll run a dedicated way from the board and tell you why up front."
          }
        },
        {
          "@type": "Question",
          "name": "Do you supply the fittings or can I buy my own?",
          "acceptedAnswer": {
            "@type": "Answer",
            "text": "Either. If you buy your own we'll check the IP rating and suitability before installing, and tell you honestly if it is not fit for the position."
          }
        },
        {
          "@type": "Question",
          "name": "Can you power my CCTV cameras and recorder?",
          "acceptedAnswer": {
            "@type": "Answer",
            "text": "Yes. We install permanent, labelled, RCD-protected supplies for cameras, PoE switches, NVRs and video doorbells, and work alongside your CCTV installer if you have one."
          }
        },
        {
          "@type": "Question",
          "name": "Will the PIR trigger constantly?",
          "acceptedAnswer": {
            "@type": "Answer",
            "text": "Not if it is set up properly. We tune sensitivity, detection zone, dwell time and lux threshold on site rather than leaving it on factory defaults."
          }
        },
        {
          "@type": "Question",
          "name": "Do you install lighting in alleyways and rear yards?",
          "acceptedAnswer": {
            "@type": "Answer",
            "text": "Yes, including shared alleys and rear entries, which are the most common problem spot on Liverpool terraces."
          }
        },
        {
          "@type": "Question",
          "name": "Is outdoor electrical work certified?",
          "acceptedAnswer": {
            "@type": "Answer",
            "text": "Yes, tested to BS 7671 with a Minor Works or Electrical Installation Certificate, and RCD protection on every outdoor circuit."
          }
        },
        {
          "@type": "Question",
          "name": "Do you cover commercial yards and car parks?",
          "acceptedAnswer": {
            "@type": "Answer",
            "text": "Yes, wall and column-mounted LED floods on photocell and timed control, plus emergency lighting where escape routes are involved."
          }
        }
      ]
    },
    {
      "@context": "https://schema.org",
      "@type": "BreadcrumbList",
      "itemListElement": [
        {
          "@type": "ListItem",
          "position": 1,
          "name": "Home",
          "item": "https://fixelectricalnw.co.uk/"
        },
        {
          "@type": "ListItem",
          "position": 2,
          "name": "Services",
          "item": "https://fixelectricalnw.co.uk/services"
        },
        {
          "@type": "ListItem",
          "position": 3,
          "name": "Security Lighting & CCTV Power",
          "item": "https://fixelectricalnw.co.uk/services/security-lighting"
        }
      ]
    }
  ]
---

[

Special Offer:  EV Charger Supply & Install from £795 View offer → → 

](/specials)

Liverpool, Merseyside Available day or night · 24/7 Emergency 

[info@fixelectricalnw.co.uk](mailto:info@fixelectricalnw.co.uk)[](https://www.instagram.com/fixelectrical/)

[![Fix Electrical (NW) Ltd](/__l5e/assets-v1/69bb4891-b08a-4ede-918e-ceb787b8dd74/fox-electrical-logo.png)](/)

[Services](/services)

[Areas](/areas)

[About](/about)[Our Work](/our-work)[Contact](/contact)

[Call now 07782 498471 ](tel:+447782498471)[Request Estimate](/contact)

Security Lighting & CCTV Power · Liverpool & the North West

# PIR floodlights, dusk-till-dawn and  
Security Lighting Installation in Liverpool.   
Plus proper, permanent power for cameras and doorbells. 

Weatherproof exterior lighting and dedicated CCTV supplies, installed on RCD-protected circuits and certified to BS 7671. No trailing extension leads, no plug-in bodges.

[Request A Free Estimate](/contact) [Call 07782 498471](tel:+447782498471)

15+ years in the trade · NAPIT approved · £2m insured · 24/7 emergency line

15+ years

In the trade

NAPIT approved

Registered contractor

£2m insured

Public liability

Certified

JIB Gold Card · C&G 2391

Service Overview 

## Security Lighting & CCTV Power in Liverpool, the full picture.

Everything below is what an honest, NAPIT-approved contractor will actually do for you, not what a marketing agency thinks sounds good on a website.

What it covers

Security lighting and CCTV power covers PIR-controlled floodlights, dusk-till-dawn wall lanterns, driveway and pathway lighting, alleyway and rear-yard lighting, plus the permanent electrical supplies that cameras, NVRs, video doorbells and access control need. We install and certify the electrical side: the circuits, the isolation, the weatherproofing and the containment.

Who it's for

Homeowners who have had a break-in or want to stop worrying about a dark alleyway, landlords lighting shared entrances and rear yards, shops and pubs lighting service yards and fire exits, and small industrial units lighting car parks and loading bays. Also anyone who has bought a camera system online and needs a socket or fused supply putting in the right place, correctly.

When you need it

Before the clocks go back is when most people call, but the best time is during any exterior work, a driveway relay, a rear extension, a new fence line or a garage conversion, when cable routes are open and containment is cheap. Commercially, when a fire risk assessment, insurer or licensing officer flags poor external lighting on escape routes and service areas.

Why professional matters

External lighting is the cheapest deterrent there is, and it only works if it is installed properly. Fittings with the wrong IP rating fill with water within a season, cameras fed from a plug in a shed lose power every time something trips, and outdoor circuits without RCD protection are an EICR failure and a genuine shock risk. Getting the electrical design right is what makes the difference between a system that runs for a decade and one that fails the first wet winter.

What Happens If You Leave It 

## The cost of putting it off.

Every one of these is something we see weekly. None of them get better on their own.

### Wrong IP rating outdoors

IP44 is the minimum for a sheltered exterior position and IP65 for anything exposed to direct weather. Under-rated fittings fill with water, corrode and trip the circuit.

### Cameras on temporary supplies

A camera or NVR fed from an extension lead through a window is a system that will be offline exactly when you need the footage.

### No RCD protection on outdoor circuits

Any socket or circuit likely to supply equipment outdoors needs RCD protection. Missing it is a C2 on any EICR and a real shock risk.

### Interior cable used outside

Standard twin and earth run across a wall or buried in a garden is not fit for purpose. Exterior runs need SWA or correctly rated and protected cable.

Our Process 

## How the job actually runs, start to finish.

1.  Step 1 
    
    ### Site walk & light plan
    
    We walk the property with you at the actual problem points, entrances, alleys, driveways, and agree fitting positions and coverage before quoting.
    
2.  Step 2 
    
    ### Circuit design
    
    We decide whether the load goes on an existing circuit or needs its own way in the board, and where isolation and switching should live.
    
3.  Step 3 
    
    ### Cable routes & containment
    
    SWA where it is buried or exposed, clipped and cleated runs where it is not, and proper glands at every entry point.
    
4.  Step 4 
    
    ### Install, seal & set up
    
    Fittings mounted, sealed and aimed. PIR sensitivity, timing and lux threshold set on site so lights come on when you want them and not at every passing cat.
    
5.  Step 5 
    
    ### Test, certify & hand over
    
    Circuit tested to BS 7671, Minor Works or Installation Certificate issued, and a walk-through of controls and overrides.
    

Benefits 

## Why customers stick with us.

### Correctly rated fittings

IP65 and above where the weather hits, stainless or coated fixings on coastal and exposed elevations.

### Permanent CCTV supplies

Dedicated, labelled, RCD-protected supplies for cameras, NVRs and doorbells, with sensible isolation for maintenance.

### PIR set up properly

Sensitivity, dwell time and lux threshold tuned on site, so you are not lying awake watching the drive light up all night.

### Tidy, discreet cabling

Runs planned along mortar lines and behind downpipes, not stapled diagonally across the brickwork.

### Certified and EICR-friendly

Every exterior circuit tested and certified, so it passes the next inspection rather than adding a code to it.

### Works with your installer

Happy to provide the power and containment for a CCTV or alarm specialist and coordinate first fix with them.

In Detail 

## Everything else worth knowing.

The specific materials, methods and situations that make this job go well, or badly, depending on who's doing it.

[Request A Free Estimate](/contact)

### Choosing the right fitting for the position

The three decisions that matter are IP rating, output and beam spread. IP44 suits a sheltered porch or a lantern under an overhang; anything on an open elevation, a gable end or a yard wall should be IP65 or better. Output matters less than people assume, a very bright floodlight aimed badly creates glare and deep shadow, which is worse for a camera than a moderate, well-aimed light. For driveways we generally use a wider beam at moderate output; for alleyways and side returns a narrow, lower-mounted fitting gives better usable coverage without blinding the camera or the neighbours.

### PIR, dusk-till-dawn or both

PIR-controlled lighting is the right answer for deterrence: movement triggers a bright light, which is the effect you actually want. Dusk-till-dawn is better for orientation and low-level continuous coverage, entrances, shared paths, and anywhere a camera needs a baseline light level all night. Many properties want both: a low-output dusk-till-dawn lantern at the door plus a PIR floodlight covering the drive or rear yard. We set the lux threshold so a PIR light does not trigger in daylight, and set dwell time long enough to be useful without leaving the yard lit for twenty minutes.

### Powering CCTV, NVRs and video doorbells

Most camera systems need three things from an electrician: a permanent supply at the camera or PoE switch position, a supply and a sensible location for the recorder, and a doorbell transformer or fused spur at the front door. We install a labelled, RCD-protected supply rather than relying on a nearby socket, put the NVR somewhere ventilated and not obvious to an intruder, and leave isolation so the system can be worked on safely later. Where a specialist installer is fitting the cameras, we provide first-fix power and containment to their layout and coordinate timings.

### Cable, containment and weatherproofing

Buried runs use steel wire armoured cable at the correct depth with marker tape, glanded properly at both ends and earthed through the gland. Surface runs are clipped in straight lines along mortar joints, or in conduit where they are within reach. Every entry into a building is sealed and, where practical, taken through at a downward angle so water cannot track in. On exposed and coastal elevations, around Crosby and the Wirral especially, we use stainless fixings and check the fitting's gasket rather than trusting a bead of silicone.

### Commercial security lighting and escape routes

Commercial sites have an extra layer: external escape routes and final exits need appropriate illumination, and that overlaps with BS 5266 emergency lighting rather than ordinary security lighting. We keep the two clearly separated, security and deterrent lighting on its own switched circuit, emergency lighting on maintained or non-maintained fittings with battery backup and a proper test regime. Yards, loading bays and car parks are usually best served by column or wall-mounted LED floods on a photocell with a timed override, so the site is not lit at full output all night for no reason.

### Light pollution, neighbours and aiming

A badly aimed floodlight is the fastest way to fall out with a neighbour, and complaints about artificial light can be treated as a statutory nuisance. We aim fittings downward, use shielded or asymmetric optics where a boundary is close, and set PIR detection zones so they cover your property rather than the pavement or the neighbour's garden. It also makes the lighting more effective: light that stays on your ground is light that a camera can actually use.

Common Questions 

## Security Lighting & CCTV Power, answered.

Straight answers to the questions we get on the phone every week. If yours isn't here, call 07782 498471 and ask.

### How much does security lighting cost to install?

+ 

It depends on the number of fittings, cable routes and whether a new circuit is needed. We quote a fixed price after a free on-site look.

### Can you fit lighting to an existing circuit?

+ 

Often yes, where the circuit has capacity and suitable protection. If not, we'll run a dedicated way from the board and tell you why up front.

### Do you supply the fittings or can I buy my own?

+ 

Either. If you buy your own we'll check the IP rating and suitability before installing, and tell you honestly if it is not fit for the position.

### Can you power my CCTV cameras and recorder?

+ 

Yes. We install permanent, labelled, RCD-protected supplies for cameras, PoE switches, NVRs and video doorbells, and work alongside your CCTV installer if you have one.

### Will the PIR trigger constantly?

+ 

Not if it is set up properly. We tune sensitivity, detection zone, dwell time and lux threshold on site rather than leaving it on factory defaults.

### Do you install lighting in alleyways and rear yards?

+ 

Yes, including shared alleys and rear entries, which are the most common problem spot on Liverpool terraces.

### Is outdoor electrical work certified?

+ 

Yes, tested to BS 7671 with a Minor Works or Electrical Installation Certificate, and RCD protection on every outdoor circuit.

### Do you cover commercial yards and car parks?

+ 

Yes, wall and column-mounted LED floods on photocell and timed control, plus emergency lighting where escape routes are involved.

Related Services 

## You might also need…

[

### Lighting Design & Installation

View service ](/services/lighting)[

### Domestic Electrician

View service ](/services/domestic)[

### Commercial & Light Industrial Electrician

View service ](/services/commercial)[

### Maintenance & Fault Finding

View service ](/services/maintenance)

[← Back to homepage](/)

Next Step 

## Get a straight quote on your security lighting & cctv power.

Free on-site survey. Fixed price in writing before any work starts. NAPIT-approved, £2m insured, certified and self-notified where required.

[Request A Free Estimate](/contact) [Call 07782 498471](tel:+447782498471)

Available day or night · 24/7 Emergency Call-Out 

![Fix Electrical (NW) Ltd, NAPIT approved Liverpool electricians](/__l5e/assets-v1/69bb4891-b08a-4ede-918e-ceb787b8dd74/fox-electrical-logo.png)

NAPIT-approved electrical contractors serving Liverpool and the North West. Domestic, commercial and EV charger specialists, with a 24/7 emergency line for when things can't wait.

[07782 498471 ](tel:+447782498471)[info@fixelectricalnw.co.uk](mailto:info@fixelectricalnw.co.uk)

Liverpool, Merseyside 

[@fixelectrical](https://www.instagram.com/fixelectrical/)

### Services

-   [Domestic Electrician](/services/domestic)
-   [Commercial & Light Industrial](/services/commercial)
-   [House Rewires](/services/rewires)
-   [Consumer Unit Changes](/services/consumer-unit-changes)
-   [EV Charger Installation](/services/ev-chargers)
-   [Lighting Design & Install](/services/lighting)
-   [Maintenance & Fault Finding](/services/maintenance)
-   [New Builds & Extensions](/services/new-builds)
-   [24/7 Emergency Call-Out](/services/emergency)
-   [EICR & Electrical Inspection](/services/eicr)
-   [PAT Testing](/services/pat-testing)
-   [Security Lighting & CCTV Power](/services/security-lighting)

### Areas

-   [Walton](/areas/walton)
-   [Fazakerley](/areas/fazakerley)
-   [Orrell Park](/areas/orrell-park)
-   [Aintree](/areas/aintree)
-   [Anfield](/areas/anfield)
-   [County Road / Walton Vale](/areas/county-road-walton-vale)
-   [Norris Green](/areas/norris-green)
-   [Old Roan / Aintree Village](/areas/old-roan-aintree-village)
-   [Everton & Kirkdale](/areas/everton-kirkdale)
-   [Bootle](/areas/bootle)
-   [Crosby](/areas/crosby)
-   [Kirkby](/areas/kirkby)
-   [Liverpool](/areas/liverpool)
-   [Wigan](/areas/wigan)
-   [St Helens](/areas/st-helens)
-   [Chester](/areas/chester)
-   [Manchester](/areas/manchester)
-   [Warrington](/areas/warrington)
-   [Widnes](/areas/widnes)
-   [Birkenhead](/areas/birkenhead)
-   [Bolton](/areas/bolton)

### Accreditations

-   NAPIT Approved   
    Registered Contractor 
-   JIB Gold Card   
    ECS Certified 
-   City & Guilds 2391   
    Testing & Inspection 
-   £2M Insured   
    Public Liability 

© 2026 Fix Electrical (NW) Ltd. Company No. 16347804. All rights reserved.

[Privacy Policy](/privacy-policy)[Terms & Conditions](/terms-conditions)[Cookie Policy](/cookie-policy)· Available day or night · 24/7 Emergency 

[Call Now](tel:+447782498471) [Free Estimate](/contact)

We use essential cookies to run this site, plus optional analytics cookies to see how it is used. [Cookie policy](/cookie-policy)

AcceptReject